Home Contact us


Up

RTCU X32/NX32 Firmware

 

RTCU NX32L Firmware S1.02.00 / R1.10.00
Released:  May 27, 2018.

 

 System-Firmware V1.02.00 includes the following improvements:

Enhancements:

  •  Entirely new and powerful Bluetooth API.
     
    Supports for both classic and Low-Energy Bluetooth.
  •  Time-out option (serSendXXX) when sending RS232 data over a channel supporting HW-handshake.
  •  boardSetApplication now supports that the application is placed on the internal drive or on the SD-CARD.
  •  RTCU M2M Platform Extensions can now be transferred to the device as part of the project.
  •  RTCU M2M Platform support for streaming audio.
  •  New audio routing function added: audioRoute().
  •  Application access to TCP/UDP ports below 1024.
  •  Improved RS485 performance.
  •  Enhanced performance and stability.

Bug Fixes:

  •  SD-CARD insertion was not always registered by the device.
  •  Modbus TCP slave mode did not work.
  •  CAN-bus monitor mode did not work according to documentation.
  •  The runtime could crash when using SMTP.

System firmware V1.02.00 includes, and requires, runtime firmware V1.10.00. No need for separate installation.

 

 

 

RTCU NX32L Runtime Firmware R1.08.00
Released:  March 27, 2018.

 

Runtime Firmware V1.08.00 includes the following improvements:

Enhancements:

  •  Entirely new and powerful Secure Socket API with full client/server TLS support.
  •  Support for secure FTP with TLS support (FTPS).
  •  Support for Modbus TCP over virtually all TCP/IP enabled channels (LAN, Wi-Fi and Cellular).
  •  gsmGetICCID() now returns the full length from the SIM card.
  •  New function ioInputLatchSet() to control the behaviour of outputs when an I/O extension fails.
  •  + other enhancements.

Bug Fixes:

  •  The program execution froze during a call to an Platform Extension Module (MODCALL).
  •  MODBUS communication recovery after connection loss could take very long time.
  •  SMTP did not validate the TLS certificate domain name correctly.
  •  SMTP crash when sending emails on Sundays!
  •  FTP could fail when transferring large files over a cellular connection. 
  •  Possible disconnection in some VMNO environments where switching operators are often performed.
  •  RTCU IDE communication could result in "Unexpected Runtime restart" faults.
  •  The drawLine function did not work correctly when X2 or Y2 was less than X1 or Y1.

 

 

 

RTCU NX32L Firmware S1.01.00 / R1.07.00
Released:  February 11, 2018.


This release firmware contains critical and important improvements. **An upgrade is mandatory**

System-Firmware V1.01.00 includes the following improvements:

Enhancements:

  •  Includes Runtime-firmware V1.07.00.
     
    It is not necessary to install Runtime-firmware V1.07.00 separately.
  •  Fix for the KRACK Wi-Fi vulnerability.
  •  Enhanced screen keyboard language support:
    •  English/Germanic: GB, IE, DE, BE, NL, LU, AT.
    •  French/Italian: FR, IT.
    •  Spanish/Portoguese: ES, PT.
    •  Nordic: IS, DK, NO, SE, FI, EE.
  •  Improved Wi-Fi connectivity with multiple SSID.
  •  + other enhancements.

Bug Fixes:

  •  RS485 communication could freeze during heavy communication.
  •  Wake-up on Ignition did not work correctly.
  •  PCT counter did not work after returning from pmWaitEvent.
  •  + other bug-fixes.



Runtime-Firmware V1.07.00 includes the following improvements:

Enhancements:

  •  Enhanced support for digital input when operating in S0 mode.
  •  Enhanced Wi-Fi performance.
  •  serOpen / serClose performance optimization.
  •  New root-certificates.

Bug Fixes:

  •  DHCP did not work correctly at re-insertion of LAN cable.
  •  Re-connection to RTCU Gateway did not always succeed with multiple interfaces active.
  •  Cases of spurious reset with "Unexpected runtime restart".
  •  Using TLS with SMTP did not always work.
  •  boardVersion() returned incorrect information.
  •  + other bug-fixes.


Please note that this release is a full system update composed of two firmware updates: System- and Monitor-Firmware.
It is very important that the RTCU IDE V9.10 (or a later version) is installed first, and then updates are applied in the following order:

  1. Monitor-Firmware V1.01.00
  2. System-Firmware V1.01.00

Failure to observe the installation order will result in an incomplete system-update.

 

 

RTCU NX32L Firmware S1.00.07 / R1.06.00
Released:  December 25, 2017.


This release firmware contains critical and important improvements. **An upgrade is mandatory**

System-Firmware V1.00.07 includes the following improvements:

Enhancements:

  •  Includes Runtime-firmware V1.06.00.
     
    It is not necessary to install Runtime-firmware V1.06.00 separately.
  •  In some cases, the device will not start-up when power is applied.
  •  Installed certificates will no longer require re-installation after a system update.
  •  + other enhancements.


Runtime-Firmware V1.06.00 includes the following improvements:

Enhancements:

  •  Functionality to save runtime crash dump file to the internal flash drive.
     SOS entry 'diagnostic.runtime.create_dump' must be set to '1'. If the run-time crashes a dump file is created in "B:\SYSTEM\DUMP".
     Please send the dump file to support@logicio.com for analysis.

Bug Fixes:

  •  CAN filters for a short range was not correctly created.
  •  Memory exhaustion when running MQTT for a long time over Wi-Fi.
  •  Transfer of runtime-firmware sometime failed.
  •  + other bug-fixes.


Please note that this release is a full system update composed of two firmware updates: System- and Monitor-Firmware.
It is very important that the RTCU IDE V9.10 is installed first, and then updates are applied in the following order:

  1. Monitor-Firmware V1.00.07
  2. System-Firmware V1.00.07

Failure to observe the installation order will result in an incomplete system-update.

 

 

 

RTCU NX32L Firmware S1.00.04 / R1.04.00
Released:  October 17, 2017.


System-Firmware V1.00.04 includes the following improvements:

Enhancements:

  •  Support for the RTCU M2M Platform SDK.
     
    MODCALL functionality added.
  •  Includes Runtime-firmware V1.04.00.
     
    It is not necessary to install Runtime-firmware V1.04.00 separately.
  •  Support for remote access to files that are in use (RACP/IDE).
  •  Functionality to calibrate the touch-screen. 
  •  Functionality to adjust the LCD-Display contrast.
  •  New displayGetKey functionality to signal key-press outside controls and backlight dimming.
  •  Enhanced Bluetooth and Wi-Fi stability.
  •  + other enhancements.

Bug Fixes:

  •  In some cases reset was required to start the device after applying power.
  •  USB host port did not always control USB-hubs and certain devices correctly.
  •  TCP/IP socket reception sometimes failed after interface re-open.
  •  Ethernet was incorrectly powered on start-up.
  •  Runtime crash when using MQTT with certain password lengths.
  •  Application version was shown incorrectly in the 'About' dialog.
  •  + other bug-fixes.


Please note that this release is a full system update composed of two firmware updates: System- and Monitor-Firmware.
It is very important that the RTCU IDE V9.10 is installed first, and then updates are applied in the following order:

  1. Monitor-Firmware V1.00.04
  2. System-Firmware V1.00.04

Failure to observe the installation order will result in an incomplete system-update.