snmpPublishOID (Function)

Top  Previous  Next

Architecture:

NX32L

Device support:

All NX devices

Firmware version:

1.60.00


Publish an OID variable.

The published variable can be read from any authenticated SNMP device on an authorized network.

Use snmpGetOID to read the variable from an RTCU device.

 

Input:

V : STRING

The OID value as a (string) to publish.

 

OID : STRING

The OID representing the variable to publish.

 

Writable : BOOL (Default false)

Give permissions to write to this variable with snmpSetOID.

 

Output:

None.

 

 

Returns: INT

1

- Success.

0

- This function is not supported.

-10

- Invalid input OID.

-12

- General error.

-14

- OID was published with another type.

-15

- Maximum amount of published OIDs reached. See limitations on overview page.

 

Declaration

FUNCTION snmpPublishOID : INT;
VAR_INPUT
  v        : MANDATORY STRING;
  oid      : MANDATORY STRING;
  writable : BOOL := FALSE;
END_VAR;

 

Example:

// Please see the example at Examples - SNMP Client.