RTCU LX Firmware

 

Runtime-firmware V2.26.00
Released:   February 27, 2024.

 

Runtime-firmware V2.26.00 includes the following improvements:

Enhancements:

Bug Fixes:

  •  A defective SD-CARD could result in the device not being able to boot.
  •  Unreliably 1-wire device communication in a "busy" device with many threads.

 

 

Runtime-firmware V2.24.00
Released:   November 12, 2023.


Runtime-firmware V2.24.00 includes the following improvements:

Enhancements:

  •  RTCU LX2 pro: Enhanced performance and stability (Upgrade is recommended).
  •  Revised list of TLS certificates.
  •  Support for SNI (Server Name Indication) when using TLS.

Bug Fixes:

  •  serSetHandshake did not work.
  •  gnssSatellitesInView did not always include all satellites in view.
  •  Using 'ld' with PCT did not include uncounted pulses.
  •  LX devices: Incorrect time reported after returning from pmSuspend.
  •  LX2: The device stops connecting to the RCH after some time.
  •  LX2: gpsGetAntennaStatus did not work reliably.
  •   + other minor bug fixes and enhancements.



 

 

Runtime-firmware V2.20.00
Released:   July 24, 2023.


Runtime-firmware V2.20.00 includes the following improvements:

Enhancements:

Bug Fixes:

  •  PowerDown / pmPowerdown did not complete when GNSS / Cellular turned on. The device ending up resetting.
  •  Wrong device time returned after exiting from power saving mode.
  •   + other minor bug fixes and enhancements.



This Runtime-firmware version requires System-firmware V1.06.00 and RTCU IDE V9.96 is recommended.

 



Runtime-firmware V2.16.00
Released:   April 2, 2023.


Runtime-firmware V2.16.00 includes the following improvements:

Enhancements:

  •  Enhanced GNSS antenna detection on the RTCU LX5.
  •  Better processing of device reset when calling boardReset and pressing the reset button.

Bug Fixes:



This Runtime-firmware version requires System-firmware V1.06.00 and RTCU IDE V9.94.

 



Runtime-firmware V2.14.00
Released:   January 27, 2023.


Runtime-firmware V2.14.00 includes the following improvements:


Enhancements:

  •  Improved backward compatibility with X32/NX32 applications.
     Possible fix to unexplainable cases of device fault with "Illegal string-id referenced" or "Reference-decrement on no-reference dynamic string detected".
  •  Enhanced device performance and stability.
     Possible fix to unexplainable cases of device faults or unexpected resets.


This Runtime-firmware version requires System-firmware V1.06.00 and RTCU IDE V9.94.

 

 

Runtime-firmware V2.13.00
Released:   December 14, 2022.


 

Enhancements:

  •  Enhanced support for Dual-SIM card devices with advanced APN settings.
  •  Faster establishment of a data connection (GPRS).

 Bug Fixes:

  •  Sending a text SMS with a length of more than 155 characters could reset the device.


This Runtime-firmware version requires System-firmware V1.06.00.

 

 

 

Runtime-firmware V2.12.00
Released:   November 10, 2022.


Runtime-firmware V2.12.00 includes the following improvements:

 Bug Fixes:

  •  Possible Datalogger corruption on the latest generation of devices.
  •  + other minor bug fixes.

 

This Runtime-firmware version requires System-firmware V1.06.00.

 

 

System-firmware V1.06.00  / Runtime-firmware V2.11.00
Released: October 26, 2022

 

System-firmware V1.06.00 / Runtime-firmware V2.11.00 includes the following new features and improvements:

Bug Fixes:

  •  Potential FRAM persistent memory corruption after powerdown.
  •  RTCU LX4 pro issues:
    •  Digital input update latency was too long.
    •  Spurious "Enter code" message on the LCD display at startup.
    •  Keypad did not work after upgrade to S1.05.00.
    •  Application control of the LCD display backlight did not work.
  •  pmPowerDown did not always work when the timeout period was short.
  •  Initial debug messages from the application were sometimes not shown in the RTCU IDE.
  •  + other minor bug fixes.

 

 System-firmware V1.06.00 includes Runtime-firmware V2.11.00. Requires RTCU IDE V9.94.

 

 

 


System
-firmware V1.05.00  / Runtime-firmware V2.10.00
Released:  October 2, 2022.

 

System-firmware V1.05.00 / Runtime-firmware V2.10.00 includes the following new features and improvements:


Enhancements:

  •  Comprehensive REST and HTTP API with functionality to work both as a server and client.
  •  JSON API with advanced functionality to create and manipulate JSON objects.
  •  Powerful String template support.
  •  Full support for static strings with a length of up to 16384 characters.
  •  Mobile data communication statistics are now supported on NX/LX devices.
  •  Faster WLAN connection to certain APs.
  •  + other minor improvements.

 Bug Fixes:

  •  Pressing the reset button to enter recovery mode did not work when running from the battery. 
  •  mqttWaitEvent could hang if the connection was closed.
  •  The primary/secondary Modbus I/O Extension Net port did not work on the RTCU LX4.
  •  + other minor bug fixes.


 
System-firmware V1.05.00 includes Runtime-firmware V2.10.00. Requires RTCU IDE V9.94.

 

 

 

 

Runtime-firmware V2.02.00
Released:   July 2, 2022.

 

Runtime-firmware V2.02.00 includes the following improvements:

Enhancements:

  •   Much faster and improved handling of certificates.

 Bug Fixes:

  •  Possible crash when playing audio over the cellular interface.
  •  Spurios crash when operating in Modbus slave mode.
  •  gsmPower could hang if the APN was incorrect.

     

This Runtime-firmware version requires System-firmware V1.04.00.

 

 

 

System-firmware V1.04.00  / Runtime-firmware V2.00.00 / Monitor-firmware V2.00.00
(CRITICAL UPGRADE)
Released:  April 18, 2022.

IMPORTANT:
This is a critical firmware upgrade that *must be installed* to avoid potentially failing devices that are unable to boot.


System-firmware V1.04.00 / Runtime-firmware V2.00.00 / Monitor-firmware V2.00.00  includes the following improvements:

Enhancements:

  •  Flexible debounce support when using high-speed PCT inputs.
  •  Enhanced boot safety and recovery.

 Bug Fixes:

  •  In rare cases, the device is unable to boot due to failed low-level recovery.
  •  The internal drive is in some cases completely lost.
  •  Entering power-saving mode could sometime fail.
  •  Delay in the RS485 data flow could result in communication errors.
  •  The backlight was not always restored on the RTCU LX4 pro at keypress.
  •  hsioEncoderReset with wait=1 in mode 0 did not work.
  •  Encryption in the RCH Fallback profile did not work.


Installation steps and instructions:
Step 1.
Transfer Monitor-firmware V2.00.00 to the device and reboot.
Step 2.
Transfer System-firmware V1.04.00 to the device and reboot.
This step also installs Runtime-firmware V2.00.00
Step 3.
Check in the system information that the expected firmware versions have been successfully installed.
Note that it is impossible to read out the Monitor version until the System-firmware has been applied.

When using the RDS the same steps should be observed, but after the Monitor-firmware has been transferred the RDS will report a "version mismatch" until the System-firmware has been applied.
For any questions, please write support@logicio.com.
 

 System-firmware V1.04.00 includes Runtime-firmware V2.00.00. Monitor-firmware V2.00.00 must be installed separately.

 


 

 

 

Runtime-firmware V1.98.00
Released:  March 6, 2022.


Runtime-firmware V1.98.00 includes the following improvements:

Enhancements:

  •  Improved CAN bus timing for enhanced performance and compatibility.
  •  Enhanced power saving mode support with reduced power consumption.
  •  pmDeepSleep now enters a true power saving mode.
  •  The Navigation/FMI API is now fully supported.
  •  Better RF ISM performance.

 Bug Fixes:

  •  The 1-wire interface did not work after resuming from a power saving mode.
  •  M-Bus API could hang during configuration.
  •  The GNSS interface was not handled correctly when entering/exiting from power saving modes.


This Runtime-firmware version requires System-firmware V1.02.00.

 


Runtime-firmware V1.96.00
Released:  December 23, 2021.


Runtime-firmware V1.96.00 includes the following improvements:

Enhancements:

  •  New and powerful M-Bus API for the  RTCU LX4 pro and the RTCU NX-400.
  •  Improvement in the CAN ISO-TP implementation.
     Supports extended CAN id's and up to 64 sessions on each CAN channel.
  •  Update of GlobalSign Root CA Certificates (R1, R3, R6).

 Bug Fixes:

  •  Opening/closing a data session (GPRS) could stop working after a long time.
  •  Entering suspend did not succeed after a certain period of time.
  •  Local variables in a callback function were not initialized to zero.


This Runtime-firmware version requires System-firmware V1.02.00.

 

 

Runtime-firmware V1.92.00 for LX devices
Released:  September 6, 2021.

Runtime-firmware V1.92.00 for LX devices includes the following improvements:

Bug Fixes:

  •  On some devices, boardTemperature() showed too high a temperature.
  •  DHCP did not always work over LAN/WLAN.


Runtime-firmware V1.92.00 requires System-firmware V1.02.00.

 

 

Runtime-firmware V1.91.50
Released:  July 10, 2021.

Runtime-firmware V1.91.50 includes the following improvements:

Bug Fixes:

  •  Using GPS/GNSS creates an NMEA logfile placed at the internal drive as "system\log\nmea.log".
     This file was intended for internal development purposes.
     


Runtime-firmware V1.91.50 requires System-firmware V1.02.00.

 

 

RTCU LX5 series System-firmware V1.02.00
Released:  July 4, 2021.

RTCU LX5 series Delta System-firmware V1.02.00 includes the following improvements:

Bug Fixes:

  •  In some cases, the CAN bus did not work reliably.


NOTE: This is a delta firmware that requires that System-firmware V1.01.00 is already installed.


System-firmware V1.02.00 includes Runtime-firmware V1.90.00.

 

RTCU LX5 series System-firmware V1.01.00
Released:  May 15, 2021.

RTCU LX5 series Delta System-firmware V1.01.00 includes the following improvements:

 
Enhancements and new functionality:

  •  Improved system performance and latency.
  •  Full audio support, including voice calls and DTMF.
  •  Hot-plug of the SD-CARD is now supported.
  •  Enhanced handling of routing when using multiple network interfaces.

Bug Fixes:

  •  Possible crash when using WLAN.
  •  The JWT API did not work.
  •  Wake-up from a CAN event did not work.


NOTE: This is a delta firmware that requires that System-firmware V1.00.01 is already installed.

System-firmware V1.01.00 includes Runtime-firmware V1.90.00.